30 40 50 GPS Surveying – System 500 Equipment List. 2 GPS Receivers and Antennas 1. GPS Receivers Select the GPS receiver 667 120 SR510 single-frequency survey receiver. Recommended model for all Leica batteries. Will charge 2 GEB121 plug-in batteries and 2 GEB71 external batteries. Intelligent charging - will not overcharge. O Ensure that the Leica DM500 microscope is used only by qualified personnel. O Ensure that this user manual is always avail - able at the Leica DM500 microscope. O Carry out regular inspections to make certain that the authorized users are adher - ing to safety requirements.
50
40
30
GPS System 500
Version 4.0 Neon service manual download 1999.
English
GPS Equipment User Manual
Advertising
Table of contents- System description
- Receiver Hardware
- Getting started with the new Survey equipment
- SKI-Pro (SKI-Pro-L1) post-processing software
- Getting started with the new MC equipment
- Getting started with the new RS equipment
- RS500 - Introduction
- Getting Started with the new GIS equipment
- Introduction
- Care and Transport
- Safety Directions
- Intended use of instrument
- Technical Specifications
Popular Brands
Popular manuals
Advertising
![User User](https://i.ebayimg.com/images/g/vzUAAOSw8GNdviW0/s-l1600.jpg)
30
GPS Equipment User Manual - 4.0.0en
Getting started with the new Survey equipment
Leica Application Suite User Manual
The antenna mounting point should
have a 5/8' thread and an unambigu-
ous reference point both horizantally
and vertically to which the antenna
phase centre can be referenced to.
have a 5/8' thread and an unambigu-
ous reference point both horizantally
and vertically to which the antenna
phase centre can be referenced to.
The equipment should ideally be in a
secure location with a reliable power
supply. An uninterruptable power
supply with sufficient backup capacity
for the local power conditions is
recommended. The equipment
should be protected against lightning
or static electrical discharge as
discussed further within the Safety
Directions of this manual.
secure location with a reliable power
supply. An uninterruptable power
supply with sufficient backup capacity
for the local power conditions is
recommended. The equipment
should be protected against lightning
or static electrical discharge as
discussed further within the Safety
Directions of this manual.
Connect the antenna to the sensor
using the supplied antenna cable.
Kinks, cut and crushed areas of the
antenna cable may degrade signal
quality and strength. It is recom-
mended that the antenna cable be
protected from long term damage.
using the supplied antenna cable.
Kinks, cut and crushed areas of the
antenna cable may degrade signal
quality and strength. It is recom-
mended that the antenna cable be
protected from long term damage.
Connect a 12VDC power supply to
the PWR port of the RS500, or insert
the internal camcorder batteries for
short term operation.
the PWR port of the RS500, or insert
the internal camcorder batteries for
short term operation.
For general configurations, system
data transfers from/to the PC card
and viewing status information attach
the TR500 terminal to the sensor,
either directly or via a connection
cable by plugging it into the TERMI-
NAL port on the sensor.
data transfers from/to the PC card
and viewing status information attach
the TR500 terminal to the sensor,
either directly or via a connection
cable by plugging it into the TERMI-
NAL port on the sensor.
For configuration and operation like
data logging and real time data
transmission connect the sensor to a
PC using the data cable (Art. No. 560
254). The PC should be running an
appropriate application program such
as Leica Geosystems
ControlStation™.
data logging and real time data
transmission connect the sensor to a
PC using the data cable (Art. No. 560
254). The PC should be running an
appropriate application program such
as Leica Geosystems
ControlStation™.
Insert a PC-card into the sensor, if no
internal memory option is installed.
internal memory option is installed.
Lock the lid carefully after
insertion of the card in order
to prevent water and dust
from getting inside the
sensor.
insertion of the card in order
to prevent water and dust
from getting inside the
sensor.
Use the hook on the backside of the
sensor to hang it on one of the tripod
legs or leave the sensor inside the
shipping case. The mounting bracket
(Art. No. 722 105) may be used to
attach the RS500 receiver firmly to a
bench, table or wall.
sensor to hang it on one of the tripod
legs or leave the sensor inside the
shipping case. The mounting bracket
(Art. No. 722 105) may be used to
attach the RS500 receiver firmly to a
bench, table or wall.
Your RS500 sensor is now fully ready
for operation.
for operation.
See Fig. RS.01 for a basic connection
scheme.
scheme.
Setting up the RS equipment, continued
Leica Gps Systems
Getting started with the new RS equipment
Leica Gps System 500 Manual
Advertising
Leica Gps Network
![Leica Gps System 500 User Manual Leica Gps System 500 User Manual](https://9409f0dc4580e894936fbde475eda04d.mesnotices.fr/cover-manual/LEICA/GPS-SYSTEM-500/06-01-15-11-01-14-528984.jpg)
Leica Q2 User Manual
Popular Brands
Aonerex Gps User Manual
Popular manuals